Your stalls are busiest in the afternoon and nearly idle overnight, because that is when drivers drive. A stall used overnight, below the station's monthly peak demand, adds energy cost and almost no new fixed cost, so every overnight kWh you sell spreads the capital and demand charges you already pay. The buyers who want those hours are robotaxi fleets, which charge between shifts when rider demand is lowest.
A public fast charger's day, and what can fill each part of it
HoursWhat usually happensWhat it costs youWhat can fill it
Noon to 7 p.m.Peak use; busy metros approach capacity (Las Vegas 45.5%, Miami 40.2% peak-hour utilization in Q2 2025)3Sets your monthly peak kW, so your demand chargeNothing; protect it for drivers
7 p.m. to 11 p.m.Tapering evening useEnergy cost per sessionEvening price or membership offers
11 p.m. to 6 a.m.Stalls mostly idleCapital, software and demand charges keep accruing with no revenueOff-peak pricing; scheduled AV fleet charging
6 a.m. to noonRising commuter and errand useEnergy cost per sessionMorning pricing

How busy is the average US fast charger in 2026?

About one-sixth of the time. Paren, which tracks public fast-charger sessions, reported national utilization of 15.76% for Q2 20261 and 15.9% for Q3 2026, across a network that passed 80,000 fast-charging ports in Q3.2

Paren defines utilization as the share of tracked time a charger spends on successful or unsuccessful charging activity.1 At 15.9%, a stall is in use about 3.8 hours a day and idle about 20.2. The average hides a wide spread: in Paren's Q2 2025 data, peak-hour utilization ran from 45.5% in Las Vegas to 12.5% in St. Louis.3

Where profitability sits is a matter of estimate. Stable Auto, a fast-charging analytics firm, puts the break-even near 15% utilization.7 McKinsey's October 2023 model of a typical California owner-operator broke even only if utilization rose from 15% to 20%, or the price rose.8 Either way, the gap between today's average and comfortable profit is a few points of utilization, and the empty overnight hours are the cheapest place to find them.

When during the day do DC fast chargers actually get used?

In the afternoon. The National Renewable Energy Laboratory studied 3,705 public Level 2 and DC fast stations from 2019 to 2022 and found DC fast charger use peaks between 2 and 6 p.m. on weekdays and weekends, at every venue type.4

The same study found DC fast stations are busier on weekends, by 14% (offices) to 54% (hotels) over weekday averages, the reverse of Level 2.4 Paren measures its peak window as noon to 7 p.m.3 Overnight sits at the bottom of every one of these curves, because the people who drive public EVs are asleep.

Treat national curves as a starting point, not your answer. Pull 90 days of session starts and stops by stall, bucket them by hour, and look for the hours where occupancy stays under one stall in four. At most suburban and highway sites that band sits inside 11 p.m. to 6 a.m.; sites near airports, hospitals or 24-hour retail can differ, and the exercise shows you which you have.

Why do empty overnight stalls cost more than they look?

Because the biggest costs do not stop at night. Under some tariffs, demand charges can make up as much as 90 percent of a fast charger's monthly bill,5 and they are set by your highest-demand moments, not by how many kWh you sell.

NREL's 2019 study of electricity rates for DC fast charging found that low utilization leads to significantly higher electricity cost, particularly under rates with demand charges, and that the cost falls rapidly as utilization rises.6 Add the capital cost of the hardware, network software fees and maintenance, and most of a station's cost is fixed per month.

That is what makes the overnight hours unusual. A session at 2 a.m. that stays below the kW your afternoon peak already set adds the energy cost and almost nothing else, so every kWh sold in those hours spreads the same fixed costs over more revenue. Where your utility has time-of-use rates the energy is often cheaper overnight too, which shows in Paren's Q3 2026 average posted prices: $0.637 per kWh at peak and $0.438 off-peak.2

One exception: some EV rates cap billed demand by the energy you sell. On FPL's GSD-1EV, billed demand can never exceed the month's kWh divided by 75 hours,9 so on a quiet station each added kWh raises billed demand until it reaches your real peak. Check your rate schedule for a limiter before you count overnight energy as nearly free.

What can fill a fast charger between 11 p.m. and 6 a.m.?

Three things, in rising order of volume: a lower overnight price, overnight memberships or accounts, and scheduled charging for robotaxi fleets. Price alone rarely moves the overnight band much, because few retail drivers are out at 3 a.m. to respond to it.
Ways to fill the overnight hours
OptionHow it fills the nightMain tradeoffBest for
Overnight time-of-use priceRewards drivers who can choose when to chargeRetail drivers are scarce overnight; discounts mostly reprice charging that would happen anywaySites near apartments without home charging
Overnight memberships or accountsLocks in repeat overnight users at a set rateSmall numbers; billing and support overheadUrban sites with a known local base
Scheduled AV fleet chargingRobotaxis arrive in a planned window and fill stalls for hoursSomeone has to plug the cars in, and the fleet must yield to driversSites with four or more fast stalls in or near a robotaxi service area

Only 27.1% of operators use time-of-use pricing,2 so an overnight price is still a lever most networks have not pulled. It just runs out of buyers at night. Robotaxi fleets are the buyer that exists at those hours: rider demand falls overnight, so a fleet can take cars out of service then and charge them where they will start the morning. Our working assumption is that a fleet would rather charge near its riders on stalls that already exist than wait for a new depot's utility connection.

When a fleet charges at your station through XoomPark, we use your unused stalls, never fill them so a retail customer can't charge, and never make you go over your monthly peak. If the other stalls fill, the fleet vehicle leaves to free one.

XoomPark buys the fleet's electricity from you at an agreed bulk rate, sends cars only to the stalls and hours you make available, and agrees power controls so charging can slow or pause at your peak. A named on-site attendant, employed by your network or the property owner, plugs in and unplugs. See robotaxi charging for fast-charging networks.

Our model: what overnight robotaxi sessions add to a four-stall site

Between about 5 and 9 points of utilization and 88,000 to 175,000 kWh a year, on our stated assumptions. A four-stall site at the national average of 15.9% would move to roughly 21% to 25%, at or above both published break-even estimates, without adding a stall or a kW of peak demand.

This is our arithmetic, not a measured result, and every input is an assumption you should replace with your own numbers.

Model inputs (our assumptions)
InputOur assumptionWhy
Fast stalls at the site4Our minimum; two stay free for drivers at all times
Stalls offered to the fleet overnight2Keeps half the site open for retail drivers
Overnight window11 p.m. to 6 a.m., 7 hoursThe quietest band on most curves above
Sessions per offered stall per night3 to 6About 45 minutes each with plug and unplug time
Energy per session40 kWhA partial top-up of a robotaxi battery

At 3 sessions per offered stall: 2 × 3 × 40 kWh = 240 kWh a night, or 87,600 kWh a year. The added busy time is 2 × 3 × 0.75 = 4.5 stall-hours out of the site's 96 a day, which lifts utilization from 15.9% to about 20.6%. The 7-hour window has room for 6 sessions per offered stall; at that pace the figures double to 175,200 kWh a year and about 25.3% utilization, with two stalls still free for drivers all night.

Every 1 cent per kWh of margin is $876 a year at the lower volume and $1,752 at the higher, for one four-stall site. Every additional 10 kWh per session adds a quarter to the kWh total. Those two sentences, with your own margin and session size, tell you what the night is worth.

What has to be true at your site for robotaxis to charge there?

Four fast stalls or more, overnight access, a connector the fleet's cars accept, and a way to slow or stop sessions remotely. The fleet also needs someone on site to plug in and unplug until robotic or wireless charging arrives.
  • Four or more fast stalls, so two stay free for drivers while fleet cars charge.
  • 24-hour access with lighting, and nothing locking the lot after the host business closes.
  • The fleet's connector: CCS, or NACS where the fleet has moved to it.
  • Remote session control through your network software, so charging can be dialed back at peak or ended when a driver arrives.
  • An agreed attendant window, and a contact for damage or a stuck connector.

What nobody knows yet: how many robotaxi fleets will charge at public sites rather than their own depots as they grow, how fast robotic plug-in arrives, and how utilities will price overnight fleet load in each territory.

When overnight AV fleet charging is the wrong move for your network

  • Your site is already busy overnight. Near airports and hospitals the night band can be full of drivers, and they come first.
  • You have fewer than four fast stalls. Two must stay free for drivers, which leaves too little for a fleet.
  • The lot closes at night or the host will not allow overnight vehicles. The deal starts with the host, not the fleet.
  • Your tariff charges demand on every hour and you cannot dial sessions back. Then overnight load can raise your bill, and the math above does not hold.
  • No robotaxi operates within reach of the site. A fleet will not drive an hour each way to charge.

Is owning an EV charging station profitable?

It depends on utilization, price and demand charges. Published break-even estimates run from about 15% utilization (Stable Auto) to about 20% (McKinsey's California example), against a national average near 16% in 2026.

What utilization does a DC fast charger need to break even?

Use the published 15% to 20% as a range, then run your own: monthly fixed costs divided by margin per kWh gives the kWh you need, and dividing by stall power and hours gives the utilization.

Do overnight sessions raise my demand charge?

Not if they stay under the peak kW your afternoon sessions already set in that billing month. That is why fleet sessions should be dialed back, not added, at peak.

Will robotaxis block my drivers?

They should not. Fleet sessions use unused stalls only, keep two stalls free, and end so a driver who arrives can charge.

Authorship

Written by XoomPark Editorial Team in collaboration with Claude Opus 5.5

Role breakdown: Topic selection and publishing by XoomPark Editorial Team; research, source checks against primary sources and draft prose by Claude Opus 5.5.